🌀 New tool Cochlea Simulator: explore the cochlea in 3D, from the travelling wave to implant stimulation. →🎧 New tool REM & RECD Workshop: measure what the device actually delivers in the ear. →🔧 New tool Device Technology Workshop: from WDRC to frequency lowering, what happens inside a hearing aid? →🎚 Simulator Audiometry Simulator: pure tones, masking and speech tests on a virtual patient. →🧩 Tool Device Selection Workshop: which device type and coupling suits which loss? →🩺 Guide Hearing & Balance Health Guide: from tinnitus to vertigo, A to Z. →🧠 Expert view In-depth pieces for clinicians, academics and graduate students. →📚 Glossary English–Turkish audiology terms, card by card. →📊 ODAK 82 assessment tools and scales in one place. →🎓 Audiology 101 Lecture notes, quizzes and case practice. →📝 New article What does Nobel-winning optogenetics mean for the future of cochlear implants? →🏛️ Congress notes IFOS 2026 Istanbul: where was hearing science at the world ENT congress? →
Home / ODAK / Turkish Matrix Sentence Test (TURMatrix)
TestAdaptationOn request

Turkish Matrix Sentence Test (TURMatrix)

Türkçe Matris Cümle Testi (TURMatrix)
Speech PerceptionNoiseHearing Loss
First author: Melanie A. Zokoll

Description

TURMatrix is an adaptive matrix sentence test that measures the speech reception threshold (SRT) in noise and in quiet. Sentences are generated at random from a matrix of ten common Turkish words in each of five categories (name, number, adjective, object, verb), giving sentences with a fixed structure that cannot be predicted. Responses can be open-set (verbal repetition) or closed-set (selecting words on screen), and the result is reported as an SRT in dB SNR. In 38 Turkish adults with normal hearing, the adaptive SRT in noise was −7.2 ± 0.7 dB SNR with open-set and −7.9 ± 0.7 dB SNR with closed-set responses.

At a Glance

RespondentPerformance test
Age groupAdult (18–64) · Older adult (65+)
Materials5 categories × 10 words
Response formatOpen (verbal) or closed (on-screen choice)
Outcome measureSRT (dB SNR)
NormsIn noise −7.2 ± 0.7 (open) · −7.9 ± 0.7 (closed) dB SNR
Slope14.1 ± 1.0 %/dB

Measured Properties

Speech reception threshold in noise and in quiet (SRT, dB SNR)

Target Population

Turkish-speaking adults; norms were obtained from adults with normal hearing. Later studies also applied it in hearing aid and cochlear implant users.

Source & Citation

Zokoll, M. A., Fidan, D., Türkyılmaz, D., Hochmuth, S., Ergenç, İ., Sennaroğlu, G., & Kollmeier, B. (2015). Development and evaluation of the Turkish matrix sentence test. International Journal of Audiology, 54(sup2), 51–61. https://doi.org/10.3109/14992027.2015.1074735
Go to source ↗

Original Scale

Original name: Matrix Sentence Test (Hagerman)

Hagerman, B. (1982). Sentences for testing speech intelligibility in noise. Scandinavian Audiology, 11(2), 79–87. https://doi.org/10.3109/01050398209076203
Go to original source ↗

Access

To access the tool, contacting the first author is recommended.

Contact: zokoll@hz-ol.de

Similar tools

← PreviousTurkish Expressive and Receptive Language Test (TİFALDİ)Next →Turkish Mobile Real-Noise Speech Discrimination Test