Canalith repositioning manoeuvres

In benign paroxysmal positional vertigo (BPPV), otoconia detached from the utricle enter a semicircular canal. When the head changes position relative to gravity, these particles slide in the canal, drag the endolymph and deflect the cupula; the result is brief vertigo and nystagmus in the plane of the canal. Diagnostic tests trigger this movement on purpose, and repositioning manoeuvres move the otoconia out of the canal and back into the utricle.

For demonstration. Performing these manoeuvres on a patient requires a clinical examination that considers contraindications, and hands-on training.

1

Interactive manoeuvre

Choose a test or manoeuvre and play it. The patient's head position is calculated at every moment; the movement of the otoconia in the canal, the deflection of the cupula and the resulting nystagmus are generated from this position. Change the patient type to see what the same manoeuvre does in a different type of BPPV.

Test or manoeuvre
Affected ear

Dix-Hallpike test

Loading 3D model…

Drag to rotate, scroll to zoom

Eye viewInfrared image from videonystagmography goggles
Eye movement recordingEye position; sudden jumps are fast phases
Inside the labyrinthAffected canal, otoconia and cupula; arrow shows gravity
Cupula excitedCupula inhibitedIn canal: 14 / 14

2

How the model works

The images are not pre-drawn animations; each is the output of a physics model.

Canal geometry

The canals come from the same micro-CT scan as the labyrinth model in the Vestibular Atlas (Wimmer et al., 2019). The canal planes are aligned to human averages (Della Santina et al., 2005).

Otoconia and cupula

Otoconia settle through the viscous endolymph under the component of gravity along the canal. A particle moving in the narrow canal drags the endolymph, which deflects the cupula. The cupula returns with a time constant of a few seconds. This structure follows the principles in the work of Rajguru et al. (2004) and Obrist et al. (2016); the parameters are tuned to clinical latency and duration ranges.

Nystagmus

The stimulated canal rotates the eye in its own plane; the slow phase is in the direction driven by the canal and the fast phase beats the opposite way. Vertical canals are excited by ampullofugal and the horizontal canal by ampullopetal flow; the inhibitory response is weaker than the excitatory one (Ewald's laws). The upbeating vertical-torsional nystagmus of the Dix-Hallpike test or the geotropic nystagmus of the supine roll test therefore emerges without being scripted.

Anterior canal

In three separate micro-CT specimens (F05, F09, T02), the ampullary arm of the anterior canal slopes markedly towards the ampulla in upright sitting; the gravity model therefore produces the downbeating nystagmus seen clinically only with an unrealistically deep head hang. The progress of otoconia in the anterior canal is therefore defined schematically by head position (Yacovino et al., 2009; Bhandari et al., 2021); the direction of the nystagmus is calculated from the canal plane, as in the other canals.

Cupulolithiasis

Apogeotropic horizontal canal BPPV is modelled with otoconia attached to the cupula; the load makes the cupula sensitive to gravity. When gravity pulls the otoconia towards the canal for long enough, the particle detaches from the cupula and becomes free canal otoconia. The time and threshold needed for detachment are model assumptions.

Limitations

The model uses the bony labyrinth of a single human specimen, represents the membranous canal by the centreline of the bony canal and shows otoconial clusters as a few particles. In the horizontal canal, a particle counts as having left the canal only once it moves through the vestibule towards the utricle. The model is a teaching tool; it should not be used for clinical decisions.

3

Clinical essentials

Key recommendations of the AAO-HNS clinical practice guideline on BPPV (Bhattacharyya et al., 2017).

Try it yourself

From positional test to manoeuvre

References

The information on this page is based on sources.

    © 2026 Ahmet Alperen Akbulut, Auditory Scene (İşitme Atölyesi). All rights reserved. It may not be copied, reproduced or distributed without permission.

    This protection covers the software, interactive tools, 3D scenes and animations, the disorder, test, manoeuvre and exercise data, texts, drawings and printable outputs of the Vestibular Atlas. Linking for educational purposes and short quotations with attribution are welcome.

    Third-party components are used under their own licences: the bony labyrinth geometry is from the dataset of Wimmer et al. (2019) (CC BY 4.0, modified), the 3D patient model from CC0-licensed assets of the MakeHuman community; three.js (MIT) is used for 3D rendering. For permissions: info@isitmeatolyesi.com